Menu
My account
Request quote

existing customer

Username / E-mail:
Password:
Forgotten your password?

Invoicing information

create account

* required field
Categories
Saro Catalogue
Catalogue
News

Bottle cooler - slim, model DK 105

Bottle cooler - slim, model DK 105

Articlenumber: 325-2160
EAN code: 4017337059249
ex Works - ex VAT
Count: - +
In stock
Recommend product
I would like to become a dealer
Product description
Manufacturer Information
EU Responsible Party
- Material: (housing and interior) PCM black coated
- Double glazing, self-closing, not lockable
- LED-lighting: awning (2.4 watt), inside (0.4 watt)
and 2x on the door (3.2 watt), not separately switchable
- 4 height-adjustable black grids with price lists
- Analog Temperature Control
- Static cooling with circulation fan
- Automatic defrost
- Temperature range: +2 / +8 °C
- Connection: 230 V - 50 Hz - 0.125 kW
- Grids: 4x W 308 x D 273 mm
- Capacity: 118 liters
- Internal dimensions: W 325 x D 343 x H 1005 mm
- External dimensions: W 403 x D 455 x H 1505 mm
- 4 adjustable legs
- Weight: 63 kg
- Refrigerant: R600a
- Energy efficiency class: D (spectrum A to G)

Safety and Warning Instructions

- Place the device only on a stable, level, and non-slip surface.
- Ensure that the mains voltage corresponds to the information on the nameplate.
- After transport or tilting the device over 45 degrees, allow it to stand upright for at least 24 hours before switching it on to avoid damage to the cooling system.
- Do not block ventilation slots or openings to ensure optimal air circulation and cooling.
- Do not operate the device near heat sources or in direct sunlight.
- Children and unauthorized persons must not operate the device or be left unsupervised near it.
- Do not store flammable, explosive, or chemical substances in the device.
- Never clean the device with a water jet or immerse it in liquids to avoid the risk of short circuits and electric shock.
- Do not place hot food or uncovered liquids inside the device to prevent condensation or icing problems.
- Do not use damaged cables or plugs; replacement must be performed only by qualified personnel.
- Always switch off the device and disconnect it from the power supply before cleaning, maintenance, or extended periods of non-use.
- The device is intended exclusively for cooling and storing beverages or food; any other use may cause damage and void the warranty.
- The refrigerant is flammable; in case of damage to the cooling circuit, ventilate the room thoroughly and avoid open flames.
- After a power outage or unplugging, wait at least 5 minutes before switching the device back on to avoid damage to the compressor.
- Repairs and maintenance must only be carried out by qualified personnel.
- During transport, ensure the device's feet do not damage the power cord.
- Immediately stop operation if visible damage or malfunctions occur, and contact qualified personnel.
- Handle the glass door with care. Do not lean heavy objects against it or strike it. If cracks or damage are visible, do not use the door and have it replaced immediately by qualified personnel.
- Use only mild cleaning agents for cleaning, and clean the condenser at least monthly to prevent dust buildup.
Manufacturer: Saro Gastro-Products GmbH Sandbahn 6 46446 Emmerich am Rhein Deutschland / GERMANY info@saro.de www.saro.de